Driver for TIGON3 (BCM570X) Ethernet controller
io-net -d tigon3 [option[,option ...]] ...&
Neutrino
  | 
Use commas (,) to separate the options (not spaces). | 
 
- connector=type
    
 
- Network cable connector type:
        
- 0
            
 
- BNC
            
 
- 1
            
 
- UTP
            
 
- 3
            
 
- FIBER
        
 
        The default is automatically detected on supported hardware.
    
 
- did=devid
    
 
- Device ID.  The default is
        automatically detected on supported hardware.
    
 
- duplex=dup
    
 
- Half (0) or full (1) duplex mode.   The default is
        automatically detected on supported hardware.
If you specify duplex, specify speed as well;
if duplex alone is specified, it is ignored and both speed and duplex
are auto-negotiated.
    
 
- mac=XXXXXXXXXXXX
    
 
- MAC address of the controller.   The default is
        automatically detected on supported hardware.
    
 
- nomulticast
    
 
- Disables the driver from sending or receiving multicast
        packets. By default, multicast is enabled.
    
 
- pci=0xXXXX
    
 
- PCI index of the controller.    The default is
        automatically detected on supported hardware.
    
 
- priority
    
 
- The priority of the driver thread. The default is 21. 
    
 
- promiscuous=0|1
    
 
- If set to 1, enable the driver to pass all data packets received,
        regardless of address.
      The default is 0.
    
 
- single
    
 
- In a multiple NIC environment, stop after the first detected card.
        Default is to enable all cards found. 
    
 
- speed=10|100
     
 
- Media data rate (10Mbit or 100Mbit operation). The default is
automatically detected on supported hardware.
If you specify speed, specify duplex as well;
if speed alone is specified, the specified speed will be correctly set,
but duplex will default to half (0).
    
 
- verbose
    verbose=num
     
- Be verbose.  Specify num for more verbosity (num can be 1-4, 
the higher the number, the more detailed the output).
The output goes to slogger,
invoke sloginfo to view.
    
 
- vid=0xXXXX
    
 
- Vendor ID of the controller.  The default is
        automatically detected on supported hardware.
 
The devn-tigon3.so driver is the Ethernet controller for 
the Broadcom BCM570X.
Start io-net using the TIGON3 driver and the full TCP/IP
stack:
io-net -d tigon3 verbose -p tcpip
ifconfig en0 10.184
- /dev/io-net
 
- The directory where, by default, drivers and protocol modules add
  entries.
  For more information, the documentation for 
  io-net.
 
io-net
"Network drivers (devn-*)"
and
"Network protocol interfaces (npm-*)"
in the Utilities Summary